Issues
FMU Export fails if XI/FM output is connected to multiple inputs
Issues ID | KI8008935 | |
Status: | Published | |
Published date: | 06/10/2020 | |
Updated: | 06/10/2020 | |
Reported In: | Easy5 - EASY5 | |
Created with Version: | Easy5 (2020) |
Known Issue
Description
If an output from XI/FM (ie., an input from the FMI Master) is connected to more than one model input then the export fails.
Description
Workaround
If an XI/FM output needs to be connected to more than one Easy5 input, then connect it to a single GP/GN component, then connect the GN output to the model inputs as needed.
Solution
The following software defect report has been created to track this issue:
ESY-3786: FMU Export fails if XI/FM output is connected to multiple inputs